How to Inspect Large PCBs with Automated X-ray Inspection
Automated X-ray inspection (AXI) of large printed circuit board assemblies starts with two checks: can the assembled board move safely through the system, and can every required inspection location be imaged at a useful resolution? A board that fits inside the machine may still have joints outside its usable inspection range.
Check Inspection Access Across the Assembled Board
Review board dimensions, weight, component heights on both sides, and fixture clearance against the proposed system configuration. Check access to joints near the edges as well as those in the center. If angled views are needed, confirm that tall components and the fixture allow the required imaging positions.
Board support also affects repeatability. Sag or warpage can change the local imaging geometry, especially when a program moves between widely separated locations. Evaluate the support arrangement on populated boards and confirm how the proposed system handles local height variation. Warpage correction capabilities vary by configuration.
Build Coverage Around the Joints That Matter
A large-board AXI program should identify the components, joints, and defect types included in its coverage. Use board reference features to align inspection locations, then select imaging conditions for each area of interest. Dense metal regions and components on the opposite side can obscure a target in projection; additional views or reconstructed slices may be needed.
An overview image helps locate components, but does not establish fine-defect visibility. Where the required detail cannot be resolved in one field of view, inspect multiple local fields. If only selected joints are programmed, describe the result as selective inspection rather than full-board defect coverage.

Validate the Program at Production Conditions
Validate the AXI program with representative acceptable assemblies and independently verified defect samples where available. Repeat loading and inspection to assess positioning, image consistency, and defect decisions. Automatic positioning alone does not establish automatic defect classification; confirm which tasks the configured software performs and which findings require operator review.
Measure the complete inspection cycle, including handling, image acquisition, reconstruction where used, and result review. Link findings to the board ID and component location so a flagged joint can be found again. For a configuration review with Shenzhen Wahfei Technology Co.,Ltd., provide the assembled board dimensions, component clearances, target defects, and required cycle time.